Parts shall be measured under one condition (temperature: 5~35 ℃, humidity: 45% ~ 85% R.H., atmospheric pressure: 860 ~ 1060hPa), unless standard conditions (temperature: 25±3 ℃, humidity: 60±10%R.H. atmospheric pressure: 860 ~ 1060hPa) are adjusted.
Category: Ultrasonic sensor
Keywords: buzzer | horn | materialized film
Product Description
1.Technical Parameter Measuring condition 1.Part shall be measured under a condition (Temperature: 5~35℃, Humidity: 45%~85%R.H., Atmospheric pressure: 860 ~1060hPa) unless the standard condition (Temperature: 25±3℃, Humidity: 60±10%R.H. Atmospheric pressure: 860 ~1060hPa) is regulated to measure. |
|
|||
1 |
Resonant Frequency | 40.0±1.0KHz | ||
2 |
Ringing(measuerd with rubber holder as per figure on next page) | 1.5ms max. | ||
3 |
Echo(testing distance of 1000mm) | 70mv min. | ||
4 |
Bandwidt(-6dB) F.O.M. Transmitting sound Pressure Level | 1.2KHz | ||
5 |
Nominal Impedance(Ohm) | 1000 max. | ||
6 |
Capacitance at 1KHz ±25% | 2200pf | ||
7 |
Max.Driving Voltage(pulse width 0.5ms interval 50ms) | 50VP-P | ||
8 |
Total Beam Angle -6dB | 80°±12° | ||
9 |
Operation Temperature | -30to80℃ | ||
10 |
Storage Temperature | -40to85℃ | ||
2.Dimensions Unit:mm Case(Aluminium) |
||||
3.Electrical And Acoustical Measuring Condition | ||||
Recommended Setting
|
||||
wave form
|
||||
Directional testing
|
||||
Beam Angle:Tested at 40.0Khz frequency
|
||||
2、Reliability Test After any following tests the part shall meet specifications without any degradation in appearance and performance except echo and ringing.Echo variation not exceeding 30%, residual vibration≤2.4ms.1、impact test At an acceleration of 980m/s²(100G), impact three times on each side.2、Drop Test Standard Packaging From 100±1cm(Drop on hard wood or board of 5cm thick, 10times.3、Vibration The product can withstand frequencies ranging from 10 to 55Hz, amplitude of 1.5mm, and scanning speed rate: loct/min vibration test, X, Y, Z three directions, 3 hours in each direction.4、high temperature storage The product is stored at +80 ± 3 ℃ for 1000 hours, and then stored in a strip at room temperature. Place under the piece for 24 hours.5、low temperature storage The product is stored at -40 ± 3 ℃ for 1000 hours, and then stored in a strip at room temperature. Place under the piece for 24 hours. f) High temperature and high humidity storage The product operates at a temperature of+80 ± 3 ℃ and a humidity of 85% R.H Storage for 1000h, then place at room temperature for 24 hours. g)Thermal Shock The probe is connected in parallel with a 3.9K Ω resistor at both ends, and is kept at -40 ℃± 3 ℃ for 0.5 hours. It is then heated to+80 ℃± 3 ℃ within 5 minutes and kept for 0.5 hours. After 1000 cycles, it is left at room temperature for 24 hours. |
3.Packing
Mobile two-dimensional code