Products
FHD1007R40P
FHD1007R40P
Parts shall be measured under one condition (temperature: 5~35 ℃, humidity: 45% ~ 85% R.H., atmospheric pressure: 860 ~ 1060hPa), unless standard conditions (temperature: 25±3 ℃, humidity: 60±10%R.H. atmospheric pressure: 860 ~ 1060hPa) are adjusted.
Category: Ultrasonic sensor
Keywords: buzzer | horn | materialized film
Product Description
1.Technical Parameter Measuring condition 1.Part shall be measured under a condition (Temperature: 5~35℃, Humidity: 45%~85%R.H., Atmospheric pressure: 860 ~1060hPa) unless the standard condition (Temperature: 25±3℃, Humidity: 60±10%R.H. Atmospheric pressure: 860 ~1060hPa) is regulated to measure. |
||||
1 | Resonant Frequency | 40.0±1.0KHz | ||
2 | Receiving Sensitivity at resonant frequency 0dB=1volt/μbar | -67dB min. | ||
3 | Bandwidt(-6dB) F.O.M. Transmitting sound Pressure Level | 1.2KHz | ||
4 | Nominal Impedance(Ohm) | 1200 max. | ||
5 | Capacitance at 1KHz ±25% | 2200pf | ||
6 | Max.Driving Voltage(pulse width 0.5ms interval 50ms) | 50VP-P | ||
7 | Total Beam Angle -6dB | 100°±10° | ||
8 | Operation Temperature | -30to80℃ | ||
9 | Storage Temperature | -40to85℃ | ||
2.Dimensions Unit:mm
|
||||
3.Electrical And Acoustical Measuring Condition | ||||
Recommended Setting
FC: Frequency Counter Tw: Tweeter BFO: Beat Freq. Osc. RL: Resistor Load 3.9kΩ TUT: Transducer Under Test MIC: Microphone MA: Measuring Amplifier AEC: Anechoic Chamber |
||||
Directional testing
|
||||
Beam Angle:Tested at 40.0Khz frequency
2、Reliability Test After any following tests the part shall meet specifications without any degradation in appearance and performance except SPL. SPL shall not deviate more than -5 dB from the initial value.a)impact test At an acceleration of 980m/s²(100G), impact three times on each side.b)Drop Test Standard Packaging From 100±1cm(Drop on hard wood or board of 5cm thick, 10times.c)Vibration The product can withstand frequencies ranging from 10 to 55Hz, amplitude of 1.5mm, and scanning speed rate: loct/min vibration test, X, Y, Z three directions, 3 hours in each direction.d)high temperature storage The product is stored at +80 ± 3 ℃ for 1000 hours, and then stored in a strip at room temperature. Place under the piece for 24 hours.e)low temperature storage The product is stored at -40 ± 3 ℃ for 1000 hours, and then stored in a strip at room temperature. Place under the piece for 24 hours. f) High temperature and high humidity storage The product operates at a temperature of+80 ± 3 ℃ and a humidity of 85% R.H Storage for 1000h, then place at room temperature for 24 hours. g)Thermal Shock The probe is connected in parallel with a 3.9K Ω resistor at both ends, and is kept at -40 ℃± 3 ℃ for 0.5 hours. It is then heated to+85 ℃± 3 ℃ within 5 minutes and kept for 0.5 hours. After 1000 cycles, it is left at room temperature for 24 hours. h)High temperature lifespan The product operates at+85 ± 3 ℃ for 118 hours, and then remains at room temperature for 24 hours i)Low temperature lifespan The product is operated at -40 ± 3 ℃ for 118 hours, and then left at room temperature for 24 hours. j)High temperature and high humidity operation The product operates at a temperature of 85 ± 3 ℃ and a humidity of 85% R H. Work for 375 hoursz, and then leave it at room temperature for 24 hours. k)High and low temperature characteristics The product remains stable for 30 minutes in the ambient temperature range of -40 ± 3 ℃, stable for 30 minutes in the temperature range of 25 ± 3 ℃, and stable for 30 minutes in the temperature range of+85 ± 3 ℃ |